Equipment Specifications
The following is a list of all pieces of
equipment and their specifications for the shell-and-tube heat exchanger.
1)
Shell-and-Tube
Heat Exchanger
·
Shell
Material: Carbon Steel
Length: 6.25 ft
Inside Diameter: 6.0 in
Outside Diameter: 6.60 in
Incoming pipe
diameter: 3/4 in, Schedule 40
stainless steel
Outlet pipe diameter: 1 1/4 in, Schedule 40 stainless steel
·
Tubes
Number of Tubes: 28
Number of Passes: 2, U-bend configuration
Material: Copper,
Schedule 40
Length: 6.0 ft
Inside Diameter: 5/8 in
Outside Diameter: 3/4 in
Pitch: 7/8 in,
Triangular pitch
Incoming pipe
diameter: 1 1/4 in, Schedule 40
stainless steel
Outlet pipe diameter: 1 1/4 in, Schedule 40 stainless steel
·
Baffling
Number of Baffles: 2
Baffle spacing: 30 5/8 in from tube side
50 3/4 in from tube
side
·
Holding
Tank
2)
Pump
Manufactured by: Worthington Pump Incorporated
Model: Worthington
D520
Size: 1.2X1X5
Impeller Diameter: 5.25 in
Operating Pressure: 21 psi
Incoming pipe
diameter: 1 1/2 in, Schedule 40
stainless steel
Outlet pipe diameter: 1 1/4 in, Schedule 40 stainless steel
3)
Double
Pipe Heat Exchanger
Material: Schedule 40
stainless steel
Length: 14 ft
Inside Pipe Diameter: 1 1/4 in
Outside Pipe Diameter: 2 1/2 in
4)
Valves
·
Gate
Valves
Manufactured by: Stockham
·
Ball
Valves
Manufactured by: Watts Regulator
·
Computer
Controlled Valves
Manufactured by: Honeywell
Model: Modulating
Valve Actuator ML7984
Operating Temperature: 0 to 55°C
Tube Valve Discharge
Coefficient: 29.3
Shell Valve Discharge
Coefficient: 11.7
P (for shell-and-tube): 5.0
I (for shell-and-tube): 2.0
D (for shell-and-tube): 0.000
5)
Flow
meters
Manufactured by: Brooks Instruments
Model: MT 3810
Accuracy: ±5% full scale from 100% to 10% of scale
reading
Repeatability: 0.25% full scale
Operating Temperature: -29 to 215°C
Flow Range: 3.52 to 35.2 gpm for
shell side flow meter
8.80 to 88.0 gpm for
tube side flow meter
6)
Thermocouples
Manufactured by: Omega
Model: Type T
Range: -60 to 100°C
Accuracy: 1.0°C or 0.75% above 0°C (whichever is greater)
1.0°C or 1.5% below 0°C (whichever is greater)
7)
Low
Pressure Steam
Pressure: 15 psi
Temperature: 100°C
8)
Computer
Manufactured by: Dell Systems
Operating System: Windows NT
Software: Opto-22
electronics and computer based software, Version R3.16. Copyright 1996-2000 Opto-22.